Watching an enzyme work, one shade of brown at a time
Turnip roots are full of peroxidase, an enzyme that uses hydrogen peroxide (a toxic by-product of aerobic metabolism) to oxidize other molecules, turning the peroxide into water. You will mix a turnip extract with dilute hydrogen peroxide and guaiacol, a colorless compound that peroxidase oxidizes into a brown product. The faster the browning, the faster the enzyme is working.
- Procedure 1: Develop a reliable assay and establish a baseline: an enzyme tube compared with a no-enzyme control, read every minute for 5 minutes with a 1–10 color palette or a spectrophotometer at 470 nm.
- Procedure 2: Replace the water in the enzyme tube with buffers from pH 3 to pH 10 and find the pH optimum.
- Your investigation: Test temperature, substrate concentration, enzyme concentration, heat treatment, or an inhibitor, and compare initial reaction rates.
- ENE-1.F Explain how changes to the structure of an enzyme may affect its function.
- ENE-1.G Explain how the cellular environment affects enzyme activity.
- SYI-3.A Connect variation in molecules (such as different forms of an enzyme) to an organism’s ability to survive in different environments.
- Science practices 6.C, 6.E Justify claims with evidence; predict the effects of a change in a biological system.
- Wear goggles, a lab coat, closed-toe shoes, and gloves. Guaiacol is harmful if swallowed and irritates the eyes and skin.
- Use pipette pumps or syringes. Never pipette by mouth. Use a separate, labeled pipette for each solution.
- Follow your teacher's and your school's chemical disposal rules and the SDS.
- Put used tubes and any solution with guaiacol in it (including stock) in the labeled waste container your teacher gives you. Never pour guaiacol down the drain.
- Leftover dilute (about 0.1–1%) hydrogen peroxide with no guaiacol may be rinsed down the drain with plenty of water, but only if your school's rules allow it.
- Broken glass goes in the glass container. Wash your hands before you leave.
- Inhibitors such as hydroxylamine also act on human enzymes. In this lab they appear only in the simulation; do not handle them at the bench.
Enzymes, shape, and rate
- Enzymes are protein catalysts that lower the activation energy; their shape (the active site) sets their function.
- Peroxidase uses H2O2 to oxidize guaiacol into a brown product; the faster the tube darkens, the faster the enzyme works.
- Rate rises with substrate until the enzyme is saturated (Vmax); Vmax scales with enzyme amount.
- Heat and extreme pH change the enzyme's shape; high heat denatures it for good.
- Compare treatments by the initial rate, the slope over the first minutes, against a baseline.
Enzymes are protein catalysts. They speed reactions by lowering the activation energy, the energy needed to reach the unstable transition state between reactants and products. The substrate binds in the enzyme’s active site, a pocket whose shape comes from the protein’s folding: primary structure (amino acid sequence) determines the hydrogen bonds, ionic bonds, hydrophobic interactions, and disulfide bridges that build secondary, tertiary, and sometimes quaternary structure. Anything that disturbs those interactions can change the active site and the rate.
Guaiacol, color and Beer–Lambert
Peroxidase is an enzyme that uses hydrogen peroxide to oxidize guaiacol. H2O2 is the oxidizing substrate and guaiacol is the hydrogen donor, so the products are water and oxidized guaiacol (tetraguaiacol), which is brown. Balanced, with guaiacol as C7H8O2 and tetraguaiacol as C28H24O8, it takes 4 guaiacol and 4 H2O2 to make 1 tetraguaiacol and 8 H2O:
No oxygen gas is involved in the color change. A simpler model than real life: “tetraguaiacol” is the traditional textbook name. The brown color really comes from a mixture of guaiacol oxidation products, such as 3,3′-dimethoxy-4,4′-biphenoquinone. So this equation is a simplified model used to explain the color, not an exact list of what is in the tube. As more product forms, the solution becomes darker. By measuring the change in absorbance over time, you can estimate the rate of enzyme activity.
You can rank the color against a 1–10 palette, which gives a relative rate (faster, slower, or the same). Or you can read absorbance of 470 nm light with a spectrophotometer, which gives an absorbance-based rate: the change in absorbance per minute (ΔA470/min, such as 0.083 per minute). That number is still not a concentration. To turn it into mM of product per minute you need a calibration, the Beer–Lambert law A = εlc, with the product’s molar absorptivity ε and the path length l of the cuvette.
Activation energy and Michaelis–Menten
Temperature, pH and the initial rate
Temperature speeds molecular collisions, so rate rises at first (roughly doubling for each 10 °C), but heat also shakes apart the weak bonds that hold the enzyme’s shape. Above the optimum the protein unfolds; at high temperature the unfolding becomes permanent (denaturation), and cooling does not bring the activity back. pH changes the charges on amino acid side chains in and around the active site, so each enzyme works best in a narrow pH range that often matches where it normally functions. Peroxidases from different sources have optimum pH values from 4 to 11 and optimum temperatures from 10 to 70 °C. Inhibitors bind the enzyme and reduce its activity.
A baseline is the standard reaction you compare everything else to. Because product builds up and conditions change as the reaction runs, compare treatments using the initial rate: the slope of absorbance (or color) versus time over the first minutes, when the graph is still nearly straight.
What this simulation models
- Process: Enzyme catalysis. Turnip peroxidase uses H2O2 to oxidize guaiacol into a brown product, so the tube darkens and absorbance rises as the reaction runs.
- Included: Substrate amount (saturating at high H2O2, and used up over time), enzyme amount, temperature (faster collisions, then unfolding and permanent denaturation), pH, heat treatment, the inhibitor hydroxylamine, slow enzyme inactivation, and pipetting, extract and spectrophotometer noise.
- Simplified or left out: One rate equation, with a pH curve fitted to the lab manual’s data. Real extracts vary in strength and cloudiness, and timing and palette judgments add error, so bench rates scatter more.
Before you start
Developing the assay and determining a baseline
Before you begin: Check the reaction mixture and measurement method before starting. Keep both consistent across trials so results can be compared.
Need a quick science reminder?
Absorbance is a light measurement, not concentration by itself. Compare color scores only with color scores, or absorbance rates with absorbance rates.
Before you combine the tubes: what will you see in the enzyme tube and in the no-enzyme control over 5 minutes (color, or absorbance at 470 nm), and why? Give a reason (1 to 2 sentences).
Controls
Tubes are prepared. Combine them to start trial 1.
More options
Full procedure
- Combine the substrate and enzyme tubes, cover with Parafilm, invert twice, and start the timer at once.
- Rotate the tube before each reading and record color (or absorbance) at 0, 1, 2, 3, 4, and 5 minutes. A phone photo helps.
- Match each photo to the palette and record a number from 1 to 10.
- Run at least 3 trials.
The effect of pH on peroxidase activity
Before you run the buffers: how will pH change the reaction rate? Name the pH you expect to work best and justify it using what pH does to amino acid side chains.
Controls
Reading time: 3 min (your Procedure 1 choice).
Run at least 3 trials.
More options
Full procedure
Make six tube pairs. Each substrate tube is the same as before. In each enzyme tube, replace the 6.0 mL of distilled water with 6.0 mL of a buffer (pH 3, 5, 6, 7, 8, or 10). Combine all pairs, then read each tube at 0 minutes and at your baseline time.
Test your own factor
Start from these questions: In Procedure 1, was the limiting factor of your baseline reaction the enzyme or the substrate? How could you modify the procedure to find out? and Which environmental factors that vary where organisms live could affect enzyme activity? Keep the total volume at 15.0 mL: if you add less enzyme or substrate, add that much more water.
Controls
More options
Readings: spectrophotometer, 470 nm, every minute for 5 minutes.
What controls the rate?
Need to revisit the pH investigation and enzyme-rate measurements? Review the investigation steps before interpreting your results.
How do I compare enzyme activity across conditions?
- Use one measurement method. Compare color scores with color scores or absorbance-change rates with absorbance-change rates, not a mixture of the two.
- Compare rates fairly. Use the same measurement interval and units for each trial, and describe how activity changes across pH or other tested conditions.
- Use controls and repeats. Explain what the no-enzyme control reveals and how repeated measurements affect confidence in the pattern.
- Interpret the evidence. Identify the tested condition with the greatest measured activity and discuss uncertainty without assuming that all enzymes have the same optimum.
An observed change in color or absorbance is evidence of the assay response; explain how it supports your claim about enzyme activity.
Scientific reasoning self-check (optional)
Review your explanation before submitting. These checkpoints are reminders, not automatic grading or evaluation of your writing.
- My claim compares enzyme activity across tested conditions.
- I cite color scores or absorbance-change rates using consistent units and intervals.
- I connect the trend to enzyme function and explain the role of controls.
- I acknowledge uncertainty and avoid assuming the same optimum for every enzyme.
If something is missing, revisit your measurements and revise your explanation. Your writing is not automatically scored here.
Going beyond the turnip
Save and hand in your work
Color score (1–10): relative comparison, not concentration.
ΔA470/min: absorbance change per minute, an absorbance-based rate.
Compare trials using the same method and time interval.